Pipe Stress Analysis

CAESAR II is piping design, pipe stress analysis and flexibility analysis software.

CAESAR II performs static and dynamic pipe stress analysis, and evaluates the structural loads and allowable stresses of steel and fibre reinforced plastic systems to international piping code standards.

CAESAR II links with CADWorx Plant, AFT Impulse and FE/Pipe.

 


{Title}
{Desc}
{Title}
{Desc}
{Title}
{Desc}
{Title}
{Desc}

 

Sales Contacts

 

  • CAESAR II
  • Latest version
  • Piping codes
  • Analysis options
  • Support FAQs

CAESAR II - Pipe Stress Analysis


Intergraph CAESAR II is a complete pipe stress analysis software program which has become the standard for pipe stress analysis. CAESAR II stress analysis software is used extensively and worldwide by both global and local engineering organisations.

The input graphics model of CAESAR II facilitates intuitive pipe stress analysis modelling. A CAESAR II stress analysis shows piping system flexibility, plus any areas of concern. Pipe stress analysis results, in the form of displacements, loads and stresses, are compared with international piping standards and piping codes.

CAESAR II provides for the static and dynamic analysis of piping systems. Calculation capabilities include:

  • fibre reinforced plastic
  • buried piping
  • wind, wave and earthquake loading
  • expansion joints
  • valves, flanges and vessel nozzles
  • piping components
  • nozzle flexibilities

CAESAR II models structural steel, and provides spectrum and time history analysis and automatic spring sizing.

CAESAR II includes an extensive materials database showing allowable stresses for ass commonly used piping codes, plus databases for valves, flanges and expansion joints.

CAESAR II has a bi-directional link with CADWorx Plant, Intergraph's comprehensive 3D piping and plant design software. Use Intergraph's CAESAR II and CADWorx together to achieve significant productivity gains such as CAESAR II data producing piping isometrics in CADWorx.

AFT Impulse is pipe flow calculation software that addresses the effects of waterhammer and other undesirable transients in piping systems. AFT Impulse transient force files can be imported into CAESAR II for Dynamic Time History and Response Spectrum analysis.

CAESAR II files may be imported into FE/Pipe's beam modeller for finite element analysis with shell or brick models.

CAESAR II is developed by Intergraph's renowned mechanical engineering experts. CAESAR II software is tested using stringent quality assurance standards and is fully supported by a trained team at Fern, backed up by Intergraph's software engineering programmers.

finite element analysis fea, piping stress analysis, caesar pipe stress, finite element analysis software, pressure vessel analysis, pv elite, tank analysis


 

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

CAESAR II version 5.20

Factsheet

Additions and changes in CAESAR II version 5.20:

  • Added ISO-14692 Code for FRP systems.
  • Added a Loop Optimization Wizard to assist in expansion loop design.
  • The Buried Pipe Modeller now supports the American LifeLines Alliance as a second soil stiffness method.
  • Added the Mexican Seismic Code to the Dynamic Input module for the automatic generation of response spectra.
  • Added a static seismic wizard to assist in computing G factors for ASCE, NBC, and CFE.
  • Added (10) additional wind codes to the Static Load setup.
  • Increased the permitted number of static load cases has been increased from 99 to 999.
  • Modified the valve/flange insertion routine to cut back the straight pipe length if necessary.
  • Added a number of drop lists to the Piping Input Spreadsheet to assist with input specification. These drop lists appear on the bend radius and insulation density fields.
  • Streamlined Spring Hanger Table definition through the addition of three checkboxes for: cold load design, extended range springs, and centered hot load.
  • Flange Symbols are now drawn on the piping elements if flange ratings have been requested.
  • Revised the following piping codes due to code changes: B31.1, B31.8, GPTC/Z380, ASME NC, ASME ND.
  • Moved User writeable subdirectories from below \caesarii to the %allusersprofile area.
  • Added automatic e-mail generation for Technical Support issues.
  • Improved the File Open dialog to permit the roll-back to earlier revisions of the (piping) input.
  • Added an export option for Static Output data - export to MS Excel. This is raw data only to improve export speed.

CAESAR II Version 5.20 - Technical Changes

The following changes may affect the numeric results:

  • Corrected the load vector for expansion joint bellows elements for fluid weight and insulation loads. (Corrected in Ver 5.10, 080207 build.)
  • Modified the way allowable stresses are selected (from previous elements) for non-defined materials in the material database. (Modified in Ver 5.10, 080207 build.)
  • Changed the values displayed in the stress report to Code components instead of mechanical stress values. This change can affect axial, bending, torsional, and hoop stress values. The code and allowable stress values are unaffected by this change. (This change is optional.)
  • Corrected the axial stress determination for PD-8010-2. (Corrected in Ver 5.10, 080207 build.)
  • B31.8 2007 introduced a second equation (in Chapter VIII) for the determination of the hoop stress.
  • The first (older) equation is used unless the hoop stress configuration switch is set to Lame’s Equation.
  • B31.8 2007 also changed the exponent in the SIF equation for concentric reducers.
  • Corrected material database entries for B165 N04400 for B31.3 and All Codes.
  • Corrected the determination of referenced temperature vectors in combination load cases, necessary to compute the Eh/Ec ratio for CODETI and EN-13480.

ign software, tank analysis, API 650, API 653, api 650 tank


Piping Codes

Factsheet

CAESAR II supports the following piping codes:

PIPING CODE Sort PUBLICATION DATE Sort REVISION DATE Sort
{pipingCode} {publicationDate} {revisionDate}

 


Analysis Options

Factsheet

CAESAR II supports the following analysis options:

OPTIONS Sort DESCRIPTION
{Option} {Description}

Support FAQs

Factsheet

Question

Why does CAESAR II version 5.20 throw an error message "Feature not found, or NetHL licenses all in use H0031" on program startup, but CAESAR II 4.5 works fine with local green USB ESL HASP key?

Answer

CAESAR II 5.20 requires local and Network USB HASP keys to have a firmware version of 3.21. The error number H0031 indicates that the current firmware version of your local HASP key is 2.16 which can be verified by visiting HASP Admin Control Center web page.  Click on HASP keys under Administration options menu and check the firmware version of your dongle.

Please follow these simple instructions to apply the firmware update:

Go to the \Assidrv directory located under the CAESAR II 5.20 program directory at C:\Program Files\Intergraph\CAESAR II 5.20\Assidrv and run the executable Firmwareupdate.exe and click on apply button.

Please ensure that this is the only HASP key attached to your PC. Disconnect any USB memory/flash drives prior to applying the firmware update.

The HASP key red light will blink for several seconds and then it will become steady. Now close the firmware utility and revisit the HASP web page to check and confirm the firmware version update to version 3.21.

CAESAR II 5.20 program should run correctly after this firmware update.

Question

We can not find 132 column report selection in CAESAR II 5.20 as there is no miscellaneous option check box available in the static output processor. Any idea how can I generate 132 column reports in CAESAR II 5.20?

Answer

The miscellaneous option check box for 132 column report is available in CAESAR II version 4.5 and older programs in the static output processor but in later versions i.e. CAESAR II version 5.0, 5.1 and 5.20, the 132 column report is now known as extended report.

See under standard report column where you will find restraint summary extended, stresses extended and code compliance extended reports which are all 132 column reports.

Question

The configuration file is missing after the installing CAESAR II 5.20 on a Windows XP 64 bit platform. Any idea how can I fix this problem?

Answer

This is a known issue in CAESAR II 5.20 release build 093004 which has been addressed in September build 090904.
Please download and install this build from Intergraph's web site by visiting the link.

Tank design software, tank analysis, API 650, API 653, api 650 tank


CAE Workflow

CAESAR II Workflow to PV Elite, PV Fabricator, NozzlePRO, FE/Pipe, AFT Impulse, CADWorx Plant, Stress Isometrics CADWorx Plant Professional, 3d piping design solution NozzlePRO, analyse nozzles, saddles, pipe shoes and clips FE/Pipe, finite element analysis for piping & pressure vessel industries Fluid flow modelling using AFT Impulse Enlarged view of CAESAR II stress isometric diagram Enlarged view of AFT impulse pipeline report Enlarged view of AFT Impulse main system pump trip report Enlarged image of CAESAR II stress isometric diagram Enlarged view of PV fabricator screen Enlarged view of PV Elite screen

Click on individual images for additional information and links to other products.

CAESAR II, PV Elite, steel pressure vessel design software, CodeCalc, steel Tank design software, oil storage tank design software, CAESAR 2, CAESARII, pv elite, asme piping. ASME, BS, EN, WRC, NBC, UBC, ASCE, IBC, API